Heat Pump Not Working? Here’s What To Do

When Your Heat Pump Goes Quiet: The Stakes Are Real in Greater Vancouver
It is 6:30 AM on a damp January morning in Burnaby. The Fraser Valley fog is pressing against your windows, the outdoor temperature has dropped to 2°C, and you notice something unsettling: your home is cold. The familiar, reassuring hum of your heat pump — that tireless workhorse silently moving thermal energy from outside air into your living space — has gone silent. For the millions of Metro Vancouver homeowners who have made the switch from gas furnaces to high-efficiency electric heat pumps, that silence is not just uncomfortable. It is a genuine emergency.
Unlike a gas furnace with its relatively simple ignition sequence, a modern variable-speed heat pump is a sophisticated refrigeration machine operating in reverse, managing compressor staging, refrigerant pressure differentials, defrost cycles, reversing valves, and electronic expansion valves — all simultaneously. When something goes wrong, the failure modes are numerous and the diagnostic pathway requires both technical knowledge and methodical calm. This comprehensive guide, written by BCRC Heating and Cooling’s Red Seal certified technicians, walks you through every step: from the simple DIY checks you can safely perform right now, to understanding the deeper mechanical failures that demand a licensed professional, to protecting your investment with proactive Greater Vancouver-specific maintenance strategies.
Step 1 — Before You Do Anything: Verify the Thermostat and Operating Mode
It sounds almost insultingly simple, but the single most common service call our technicians respond to in Vancouver involves a thermostat that has been inadvertently set to the wrong mode or temperature. Modern smart thermostats — Ecobee, Nest, Honeywell T-Series — are powerful tools, but they are also prone to firmware updates, Wi-Fi dropouts, and accidental setting changes that can result in the system doing absolutely nothing while appearing fully operational on the display.
Begin your diagnostic here. Check the following with precision:
- Mode Selection: Confirm the thermostat is set to Heat in winter or Cool in summer. The Auto mode relies on the thermostat’s internal temperature differential logic, which can sometimes stall in transitional weather common to the Lower Mainland.
- Setpoint vs. Ambient Temperature: The setpoint must be at least 2–3°C above the current indoor temperature to trigger a heating call. If your home is 20°C and your setpoint is 20°C, the system correctly determines it has no work to do.
- Fan Setting: Ensure the fan is set to Auto, not On. A fan set to continuous On will circulate air even when the heat pump is not conditioning it, creating the sensation that the system is running but producing no heat.
- Smart Thermostat Schedules: Review any programmed schedules or geofencing rules. An aggressive setback schedule may have dropped the target temperature lower than you expect during off-peak hours.
- Battery or Power to Thermostat: Battery-powered thermostats with low batteries can send erratic or incomplete signals to the air handler and outdoor unit. Replace batteries and observe whether the system recovers.
Step 2 — Electrical Diagnostics: Circuit Breakers, Disconnect Switches, and Fuses
Heat pump systems in Greater Vancouver typically operate on a dedicated 240-volt double-pole circuit, often between 30 and 60 amps depending on the system’s capacity. A tripped breaker is one of the most frequent causes of a sudden heat pump shutdown, and it is entirely within a homeowner’s safe reach to investigate.
Navigate to your main electrical panel and locate the breakers labeled for your heat pump or air handler. A tripped breaker will typically sit in a middle or ambiguous position between ON and OFF — it will not be flush with the other breakers. To reset it, push the breaker firmly to the OFF position first, then back to ON. Do not attempt to reset a breaker more than once if it trips again immediately. Repeated tripping is a symptom of an underlying electrical fault — a failed compressor capacitor, a locked rotor drawing excessive current, or a refrigerant system issue causing the compressor to work beyond its design limits. Forcing a repeatedly tripping breaker is a fire and equipment hazard.
Also check the outdoor disconnect box — a grey or black weatherproof enclosure mounted on the exterior wall within a metre of your outdoor unit. Many disconnect boxes contain cartridge fuses that can blow independently of your main panel. Pull the disconnect block and visually inspect the fuses, or test them with a non-contact voltage tester. Blown fuses in the disconnect box are extremely common after voltage spikes during BC Hydro grid fluctuations, particularly during summer storm events on the North Shore and in Coquitlam.

Step 3 — Inspect and Replace the Air Filter: The Most Underestimated Maintenance Task
A severely restricted air filter is responsible for a staggering proportion of heat pump performance failures and emergency shutdowns across Metro Vancouver. When the indoor air handler’s return air filter becomes clogged with dust, pet dander, and the fine particulate matter that infiltrates homes during wildfire smoke events — an increasingly common occurrence in BC summers — the system’s ability to exchange heat across the evaporator coil is catastrophically compromised.
The consequences cascade quickly. Restricted airflow across the indoor coil during cooling mode causes the coil surface temperature to drop below the dew point and then below freezing. Ice forms on the coil. As the ice layer thickens, airflow is further restricted. The refrigerant returning to the compressor becomes dangerously cold and liquid-saturated — a condition called liquid slugging — which can destroy the compressor’s reed valves within minutes. During heating mode, restricted airflow causes the system to overheat, triggering the high-temperature limit switch, which shuts the system down as a protective measure.
Check your filter now. If it has been longer than 90 days since it was last replaced — or 60 days if you have pets or live near a construction zone — replace it immediately with a filter of the correct MERV rating for your system (typically MERV 8 to MERV 11 for residential heat pumps; avoid MERV 13 or higher unless your system’s blower is specifically rated for the increased static pressure).
Step 4 — Examine the Outdoor Unit: Ice, Debris, and Airflow Obstruction
Walk outside and visually inspect the outdoor condenser/heat exchanger unit. In Greater Vancouver’s wet, mild winters, it is entirely normal for a thin layer of frost to form on the outdoor coil during heating operation — this is why all heat pumps run periodic defrost cycles, temporarily reversing refrigerant flow to melt the frost. What is not normal is a solid block of ice encasing the entire unit, encapsulating the fan blades and coil fins.
Heavy ice accumulation indicates one of several possible failures: a defrost control board fault, a defrost thermostat or sensor failure, a low refrigerant charge causing the coil to run abnormally cold, or in some cases, gutters positioned above the unit dripping water directly onto the coil. Do not attempt to chip or pry ice from the coil — the aluminium fins are extremely delicate and bend irreparably with minimal force, permanently reducing system efficiency. You can gently pour lukewarm (not hot) water over the unit to assist melting, but if the root cause is a refrigerant or control board issue, the ice will simply return.
Also clear any leaves, debris, or vegetation that may have accumulated around the unit’s perimeter. Heat pumps require a minimum of 60 centimetres of clear space on all sides and 1.5 metres of vertical clearance above the discharge fan. In Metro Vancouver’s lush landscaping environments — particularly in North Vancouver, West Vancouver, and the Tri-Cities — overgrown hedges and shrubs frequently strangle outdoor unit airflow across the summer and fall seasons.
Step 5 — Read the Error Codes: Your Heat Pump Is Trying to Tell You Something
Every heat pump manufactured after approximately 2010 is equipped with onboard diagnostics that communicate fault conditions through LED flash sequences, alphanumeric display codes, or — in Wi-Fi enabled systems — push notifications directly to your smartphone via the manufacturer’s app. These error codes are not generic warnings; they are precise engineering signals pointing to specific subsystem failures.
Common fault codes encountered on popular heat pump brands serviced throughout Greater Vancouver include:
- E1 / Communication Fault: Loss of signal between the indoor air handler control board and the outdoor unit. Often caused by damaged communication wiring, a failed control board, or a power interruption that scrambled the system’s initialization sequence.
- E4 / High Discharge Pressure: The refrigerant discharge pressure from the compressor has exceeded safe operating limits. Common causes include a dirty outdoor coil, restricted refrigerant flow from a failed expansion valve, or a refrigerant overcharge.
- E6 / Low Suction Pressure: Refrigerant pressure on the suction side of the compressor is abnormally low. This is a classic indicator of a refrigerant leak or a severely restricted metering device.
- E8 / High Discharge Temperature: The compressor discharge line is overheating — a critical warning that the compressor is under severe mechanical or thermal stress. Continued operation risks permanent compressor seizure.
- Defrost Lock-In: Some units display a continuous defrost indicator, signalling that the defrost cycle initiated but failed to complete, locking the system in a state where it cannot resume normal heating operation.
Always record the specific error code before resetting the system. This information is invaluable to your HVAC technician — it dramatically reduces diagnostic time and, by extension, your service bill.
Step 6 — The Refrigerant Refrigerant Reality: Why This Is Never a DIY Fix
If your preliminary checks reveal no obvious electrical, filter, or airflow issues, and the system continues to underperform or display pressure-related fault codes, there is a strong possibility that the refrigerant charge has been compromised. Refrigerant does not naturally deplete over time in a properly sealed system — if your charge is low, it means there is a leak somewhere in the refrigerant circuit: a brazed joint, a Schrader valve core, a corroded line set section, or a failed compressor shaft seal.
In Canada, handling refrigerants — including the R-410A that powers most current-generation heat pumps and the R-32 and R-454B found in newer ultra-high-efficiency systems — requires federal certification under Environment and Climate Change Canada regulations. Purchasing, handling, recovering, or charging refrigerants without proper certification is illegal and carries significant fines. Beyond the legal dimension, an improperly charged system can destroy a compressor worth $1,500 to $3,500 in a matter of hours. This is unequivocally a task for a licensed Red Seal HVAC-R technician equipped with calibrated manifold gauges, an electronic refrigerant leak detector, and a certified recovery machine.
Step 7 — Stay Comfortable While You Wait: Interim Heating Strategies
While you wait for professional service, maintaining safe indoor temperatures is the priority — especially if you have young children, elderly family members, or individuals with health vulnerabilities in the home. Greater Vancouver winters are mild by Canadian standards, but sustained indoor temperatures below 15°C can create genuine health risks and accelerate condensation-related moisture damage in walls and ceilings.
- Electric Space Heaters: Safe and effective for maintaining temperature in occupied rooms. Use only CSA-certified units with tip-over and overheat protection. Never leave them unattended or place them near curtains or bedding.
- Gas Fireplace or Insert: If your home has a gas fireplace, this is an excellent supplemental heat source capable of maintaining comfortable temperatures in open-plan living areas.
- Reverse Ceiling Fans: Set ceiling fans to run clockwise at low speed during winter to redistribute warm air that has stratified at ceiling level back down to the occupied zone.
- Seal Drafts: Roll up towels against exterior door thresholds. Close curtains or blinds on north and east-facing windows after dark to reduce radiant heat loss.
- Electric Baseboard Backup: Many Greater Vancouver homes with heat pumps retain their original electric baseboard heaters as a backup. If your heat pump has failed, these can be re-energized at the breaker panel to provide reliable — if less efficient — supplemental heat.
Step 8 — Greater Vancouver-Specific Maintenance: Protecting Your Investment in BC’s Coastal Climate
Metro Vancouver’s climate presents a unique set of challenges for heat pump longevity. The combination of high ambient humidity, salt air exposure in coastal communities from West Vancouver to Tsawwassen, freeze-thaw cycling during cold snaps, and the corrosive airborne particulate from wildfire smoke events creates an operating environment significantly more demanding than the temperate conditions heat pump efficiency ratings are measured under in a laboratory.
Proactive maintenance specific to BC homeowners includes:
- Annual Coil Cleaning: Both the indoor evaporator coil and outdoor condenser coil should be professionally cleaned annually. Biofilm, mould, and mineral deposits from Metro Vancouver’s hard water (particularly in Maple Ridge and Langley) accumulate on coil surfaces and act as insulation, degrading heat transfer efficiency and elevating operating pressures. Left unaddressed, this directly shortens compressor life.
- Condensate System Inspection: Greater Vancouver’s high humidity means your heat pump’s condensate drain system works hard year-round. Algae growth in drain pans and drain lines is extremely common, leading to overflow conditions that can saturate ceiling drywall in second-floor installations. Treat the condensate pan annually with condensate treatment tablets and flush the drain line.
- Electrical Connection Torque Check: Thermal cycling in our coastal environment causes expansion and contraction of electrical connections at the contactor, capacitor, and control board terminals. Loose connections arc, generate heat, and cause intermittent failures. A qualified technician should inspect and re-torque all electrical connections annually.
- CleanBC and BC Hydro Rebate Optimization: BC Hydro’s Home Renovation Rebate program and CleanBC’s Better Homes initiative offer substantial rebates — up to $6,000 in some cases — for the installation of cold-climate heat pumps meeting specific efficiency thresholds (typically HSPF2 ≥ 7.5 or COP ≥ 2.0 at -15°C). To remain eligible for these programs at your next upgrade, maintaining documented service records from a licensed contractor is frequently a program requirement. Ensure your HVAC contractor provides itemized service reports after every visit.
When to Call a Professional: Non-Negotiable Warning Signs
Certain conditions require you to stop all DIY troubleshooting immediately and contact a licensed HVAC-R technician. These include: a burning or electrical smell emanating from the air handler or outdoor unit; visible arcing, scorch marks, or melted wiring at any electrical component; the sound of grinding, clanking, or high-pitched squealing from the compressor or indoor blower motor; refrigerant hissing sounds accompanied by ice formation on the suction line; and any fault code referencing compressor overload, high discharge temperature, or communication failure that persists after a single controlled reset attempt.
Frequently Asked Questions
Why does my heat pump blow cold air during heating mode?
This is one of the most alarming symptoms homeowners report, and it has several distinct causes. The most benign explanation is a normal defrost cycle: when the outdoor coil frosts over, the heat pump temporarily reverses refrigerant flow to melt the ice, during which time the indoor unit circulates room-temperature or slightly cool air for 5–15 minutes. This is normal. However, if cold air blows continuously outside of a defrost cycle, the causes escalate in severity: a failed reversing valve stuck in cooling mode, a refrigerant charge that is too low to generate adequate heat output at current outdoor temperatures, a defective compressor that is mechanically pumping but not building pressure differential, or an auxiliary/emergency heat element that has failed in an air handler designed to supplement heat pump output during very cold weather. Each of these requires professional diagnosis.
My heat pump runs constantly but never reaches the setpoint temperature. What is wrong?
Continuous operation without reaching setpoint — called short of setpoint operation — is a nuanced diagnostic challenge. In cold weather, particularly during the sub-zero events that occasionally impact the Fraser Valley and inland areas of Metro Vancouver, it may simply mean that outdoor conditions have temporarily exceeded the design capacity of your heat pump. Most standard-efficiency heat pumps begin losing capacity significantly below approximately -8°C, and cold-climate models are rated down to -25°C but still lose capacity as temperatures drop. If outdoor temperatures are within the system’s rated range and it still cannot achieve setpoint, probable causes include a dirty coil reducing heat exchange efficiency, a low refrigerant charge reducing system capacity by 20–40%, a failing compressor with reduced volumetric efficiency, or a building envelope issue — inadequate insulation, air leakage — where heat loss exceeds the system’s output capacity.
How long should a heat pump last in the Greater Vancouver climate?
A properly installed, regularly maintained heat pump in Metro Vancouver should provide 15 to 20 years of reliable service. The coastal climate does impose additional wear compared to drier inland environments: aluminium fin corrosion on the outdoor coil is accelerated by salt air in communities within 5 kilometres of the ocean, and high ambient humidity year-round creates demanding conditions for electrical components. Compressors — the single most expensive component in the system — typically last 12 to 18 years when the system is maintained with clean coils and correct refrigerant charge. Systems that run with dirty coils or low refrigerant for extended periods frequently experience compressor failure within 7 to 10 years. Annual professional maintenance is the single most cost-effective investment a heat pump owner can make.
Should I repair or replace my heat pump if the compressor fails?
This is the most consequential financial decision in heat pump ownership. As a general rule applied by BCRC’s technicians: if the compressor failure occurs within the first 10 years and the unit is still under manufacturer’s compressor warranty (most quality brands offer 5–10 year compressor warranties), repair is typically the right choice. If the compressor fails in a system older than 12 years, replacement is almost always more economical and strategically advantageous. A new high-efficiency cold-climate heat pump will qualify for BC Hydro and CleanBC rebates, will use more environmentally responsible refrigerants (R-32 or R-454B rather than the phase-down R-410A), will deliver substantially higher HSPF2 efficiency ratings reducing your electricity costs, and will come with a fresh warranty period. The compressor in a 12-year-old system is also surrounded by other components — capacitors, contactors, control boards, fan motors — that are approaching end-of-life simultaneously, meaning a repair investment today often leads to another significant repair within 2–3 years.
Protect Your Comfort: Partner With Red Seal Certified Experts
A heat pump failure in Greater Vancouver is never just an inconvenience — it is a disruption to the energy-efficient, low-carbon comfort system you have invested in, and in our increasingly variable coastal climate, restoring it quickly and correctly is non-negotiable. The diagnostic pathway is methodical: begin with thermostat verification, work through electrical checks and filter inspection, examine the outdoor unit for ice and obstruction, record any fault codes, and escalate immediately to a licensed professional for any refrigerant, electrical, or mechanical fault beyond the scope of safe homeowner intervention. Preventive annual maintenance is not optional maintenance — it is the difference between a heat pump that serves your family for 20 years and one that requires a premature $12,000 replacement. For reliable, Red Seal certified heat pump installation in Vancouver and throughout Metro Vancouver, as well as expert diagnostics, emergency repairs, and CleanBC rebate-qualifying system upgrades, contact the local experts at BCRC Heating and Cooling today at (604) 781-7272. Our team is standing by to restore your comfort, protect your investment, and ensure your home is ready for whatever the Lower Mainland’s weather delivers next.